ZWave: setpointHeating from hschmitt, forum #23277

git-svn-id: https://svn.fhem.de/fhem/trunk/fhem@5764 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
rudolfkoenig 2014-05-06 11:33:32 +00:00
parent e8f2b5ae0b
commit 5d50fa9704

View File

@ -123,6 +123,8 @@ my %zwave_class = (
"0340031f" => "state:manual", }, } ,
THERMOSTAT_OPERATING_STATE=>{ id => '42', },
THERMOSTAT_SETPOINT => { id => '43',
set => { setpointHeating => "010101%02x",
setpointCooling => "010201%02x"},
get => { setpoint => "02" },
parse => { "064303(..)(..)(....)" => 'sprintf("temperature:%0.1f %s %s", '.
'hex($3)/(10**int(hex($2)/32)), '.
@ -851,6 +853,16 @@ s2Hex($)
set the thermostat mode to off, cooling, heating or manual.
</li>
<br><br><b>Class THERMOSTAT_SETPOINT</b>
<li>setpointHeating value<br>
set the thermostat to heat to the given value.
The value is a whole number and read as celsius.
</li>
<li>setpointCooling value<br>
set the thermostat to heat to the given value.
The value is a whole number and read as celsius.
</li>
<br><br><b>Class WAKE_UP</b>
<li>wakeupInterval value<br>
Set the wakeup interval of battery operated devices to the given value in