mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-05-01 20:20:10 +00:00
76_SolarForecast.pm: contrib 0.61.0
git-svn-id: https://svn.fhem.de/fhem/trunk/fhem@26047 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
49f7dc82b0
commit
a4458ecd14
@ -120,6 +120,9 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"0.61.0 "=> "15.05.2022 limit PV forecast to inverter capacity ",
|
||||
"0.60.1 "=> "15.05.2022 consumerHash -> new key avgruntime, don't modify mintime by avgruntime by default anymore ".
|
||||
"debug switch conditions ",
|
||||
"0.60.0 "=> "14.05.2022 new key 'swoncond' in consumer attributes ",
|
||||
"0.59.0 "=> "01.05.2022 new attr createTomorrowPVFcReadings ",
|
||||
"0.58.0 "=> "20.04.2022 new setter consumerImmediatePlanning, functions isConsumerOn isConsumerOff ",
|
||||
@ -2503,7 +2506,9 @@ sub _transferInverterValues {
|
||||
my $type = $hash->{TYPE};
|
||||
|
||||
my ($pvread,$pvunit) = split ":", $h->{pv}; # Readingname/Unit für aktuelle PV Erzeugung
|
||||
my ($edread,$etunit) = split ":", $h->{etotal}; # Readingname/Unit für Energie total
|
||||
my ($edread,$etunit) = split ":", $h->{etotal}; # Readingname/Unit für Energie total (PV Erzeugung)
|
||||
|
||||
$data{$type}{$name}{current}{invertercapacity} = $h->{capacity} if($h->{capacity}); # optionale Angabe max. WR-Leistung
|
||||
|
||||
return if(!$pvread || !$edread);
|
||||
|
||||
@ -2865,10 +2870,10 @@ sub _manageConsumerData {
|
||||
my $runhours = 0;
|
||||
my $dnum = 0;
|
||||
|
||||
for my $n (sort{$a<=>$b} keys %{$data{$type}{$name}{pvhist}}) { # gemessenen Verbrauch ermitteln
|
||||
my $csme = HistoryVal ($hash, $n, 99, "csme${c}", 0);
|
||||
next if(!$csme);
|
||||
for my $n (sort{$a<=>$b} keys %{$data{$type}{$name}{pvhist}}) { # Betriebszeit und gemessenen Verbrauch ermitteln
|
||||
my $csme = HistoryVal ($hash, $n, 99, "csme${c}", 0);
|
||||
my $hours = HistoryVal ($hash, $n, 99, "hourscsme${c}", 0);
|
||||
next if(!$hours);
|
||||
|
||||
$consumerco += $csme;
|
||||
$runhours += $hours;
|
||||
@ -2876,11 +2881,14 @@ sub _manageConsumerData {
|
||||
}
|
||||
|
||||
if ($dnum) {
|
||||
$data{$type}{$name}{consumers}{$c}{avgenergy} = ceil ($consumerco/$dnum); # Durchschnittsverbrauch eines Tages aus History
|
||||
my $mintime = ConsumerVal ($hash, $c, "mintime", $defmintime);
|
||||
my $avgruntime = (ceil($runhours/$dnum)) * 60; # Durchschnittslaufzeit in Minuten
|
||||
$mintime = $avgruntime < $mintime ? $mintime : $avgruntime;
|
||||
$data{$type}{$name}{consumers}{$c}{mintime} = $mintime;
|
||||
if($consumerco) {
|
||||
$data{$type}{$name}{consumers}{$c}{avgenergy} = ceil ($consumerco/$dnum); # Durchschnittsverbrauch eines Tages aus History
|
||||
}
|
||||
else {
|
||||
delete $data{$type}{$name}{consumers}{$c}{avgenergy};
|
||||
}
|
||||
|
||||
$data{$type}{$name}{consumers}{$c}{avgruntime} = (ceil($runhours/$dnum)) * 60; # Durchschnittslaufzeit in Minuten
|
||||
}
|
||||
|
||||
$paref->{consumer} = $c;
|
||||
@ -3361,6 +3369,7 @@ sub __switchConsumer {
|
||||
my $pstate = ConsumerVal ($hash, $c, "planstate", "");
|
||||
my $cname = ConsumerVal ($hash, $c, "name", ""); # Consumer Device Name
|
||||
my $calias = ConsumerVal ($hash, $c, "alias", ""); # Consumer Device Alias
|
||||
my $debug = AttrVal ($name, "debug", 0);
|
||||
|
||||
## Ist Verbraucher empfohlen ?
|
||||
################################
|
||||
@ -3373,9 +3382,19 @@ sub __switchConsumer {
|
||||
|
||||
## Verbraucher einschalten
|
||||
############################
|
||||
my $oncom = ConsumerVal ($hash, $c, "oncom", ""); # Set Command für "on"
|
||||
my $auto = ConsumerVal ($hash, $c, "auto", 1);
|
||||
my $swoncond = isAddSwitchOnCond ($hash, $c); # zusätzliche Switch on Bedingung
|
||||
my $oncom = ConsumerVal ($hash, $c, "oncom", ""); # Set Command für "on"
|
||||
my $auto = ConsumerVal ($hash, $c, "auto", 1);
|
||||
my ($swoncond,$info,$err) = isAddSwitchOnCond ($hash, $c); # zusätzliche Switch on Bedingung
|
||||
|
||||
Log3 ($name, 1, "$name - $err") if($err);
|
||||
|
||||
if($debug) { # nur für Debugging
|
||||
Log (1, qq{DEBUG> $name - Parameters for switch on decision consumer "$c": }.
|
||||
qq{swoncond: $swoncond, auto mode: $auto, on-command: $oncom, }.
|
||||
qq{planning state: $pstate, start timestamp: }.($startts ? $startts : "undef").", ".
|
||||
qq{timestamp: $t}
|
||||
);
|
||||
}
|
||||
|
||||
if($swoncond && $auto &&
|
||||
$oncom && $pstate =~ /planned|priority/xs && $startts && $t >= $startts) { # Verbraucher Start ist geplant && Startzeit überschritten
|
||||
@ -3418,6 +3437,15 @@ sub __switchConsumer {
|
||||
## Verbraucher ausschalten
|
||||
############################
|
||||
my $offcom = ConsumerVal ($hash, $c, "offcom", ""); # Set Command für "off"
|
||||
|
||||
if($debug) { # nur für Debugging
|
||||
Log (1, qq{DEBUG> $name - Parameters for switch off decision consumer "$c": }.
|
||||
qq{auto mode: $auto, off-command: $offcom, }.
|
||||
qq{planning state: $pstate, stop timestamp: }.($stopts ? $stopts : "undef").", ".
|
||||
qq{timestamp: $t}
|
||||
);
|
||||
}
|
||||
|
||||
if($auto && $offcom && $pstate !~ /switched\soff/xs && $stopts && $t >= $stopts) { # Verbraucher nicht switched off && Stopzeit überschritten
|
||||
CommandSet(undef,"$cname $offcom");
|
||||
|
||||
@ -6134,7 +6162,14 @@ sub calcPVforecast {
|
||||
$data{$type}{$name}{current}{allstringspeak} = $peaksum; # insgesamt installierte Peakleistung in W
|
||||
|
||||
$pvsum *= $hc; # Korrekturfaktor anwenden
|
||||
$pvsum = $peaksum if($pvsum > $peaksum);
|
||||
$pvsum = $peaksum if($pvsum > $peaksum); # Vorhersage nicht größer als die Summe aller PV-Strings Peak
|
||||
|
||||
my $invcapacity = CurrentVal ($hash, "invertercapacity", 0); # Max. Leistung des Invertrs
|
||||
|
||||
if ($invcapacity && $pvsum > $invcapacity) {
|
||||
$pvsum = $invcapacity + ($invcapacity * 0.01); # PV Vorhersage auf WR Kapazität zzgl. 1% begrenzen
|
||||
Log3 ($name, 4, "$name - PV forecast limited to $pvsum Watt due to inverter capacity");
|
||||
}
|
||||
|
||||
my $logao = qq{};
|
||||
$paref->{pvsum} = $pvsum;
|
||||
@ -7148,18 +7183,23 @@ return;
|
||||
################################################################
|
||||
# Funktion liefert "1" wenn die zusätzliche Einschaltbedingung
|
||||
# aus dem Schlüssel "swoncond" im Consumer Attribut wahr ist
|
||||
#
|
||||
#
|
||||
#
|
||||
#
|
||||
################################################################
|
||||
sub isAddSwitchOnCond {
|
||||
my $hash = shift;
|
||||
my $c = shift;
|
||||
|
||||
my $info = q{};
|
||||
my $err = q{};
|
||||
|
||||
my $dswoncond = ConsumerVal ($hash, $c, "dswoncond", ""); # Device zur Lieferung einer zusätzlichen Einschaltbedingung
|
||||
|
||||
if($dswoncond && !$defs{$dswoncond}) {
|
||||
my $name = $hash->{NAME};
|
||||
my $err = qq{ERROR - the device "$dswoncond" doesn't exist! Check the key "swoncond" in attribute "consumer${c}"};
|
||||
Log3 ($name, 1, "$name - $err");
|
||||
return;
|
||||
$err = qq{ERROR - the device "$dswoncond" doesn't exist! Check the key "swoncond" in attribute "consumer${c}"};
|
||||
return (0, $info, $err);
|
||||
}
|
||||
|
||||
my $rswoncond = ConsumerVal ($hash, $c, "rswoncond", ""); # Reading zur Lieferung einer zusätzlichen Einschaltbedingung
|
||||
@ -7167,10 +7207,12 @@ sub isAddSwitchOnCond {
|
||||
my $condstate = ReadingsVal ($dswoncond, $rswoncond, "");
|
||||
|
||||
if ($condstate =~ m/^$swoncondregex$/x) {
|
||||
return 1;
|
||||
return (1, $info, $err);
|
||||
}
|
||||
|
||||
return;
|
||||
$info = qq{The device "$dswoncond", reading "$rswoncond" doen't match the Regex "$swoncondregex"};
|
||||
|
||||
return (0, $info, $err);
|
||||
}
|
||||
|
||||
###############################################################################
|
||||
@ -7359,6 +7401,7 @@ return $def;
|
||||
# powerbatout - Batterie Entladeleistung
|
||||
# temp - aktuelle Außentemperatur
|
||||
# tomorrowconsumption - Verbrauch des kommenden Tages
|
||||
# invertercapacity - Bemessungsleistung der Wechselrichters (max. W)
|
||||
# $def: Defaultwert
|
||||
#
|
||||
#############################################################################
|
||||
@ -7401,6 +7444,7 @@ return $def;
|
||||
# upcurr - Unit des aktuellen Verbrauchs
|
||||
# avgenergy - initialer / gemessener Durchschnittsverbrauch
|
||||
# eines Tages
|
||||
# avgruntime - durchschnittliche Einschalt- bzw. Zykluszeit (Minuten)
|
||||
# epieces - prognostizierte Energiescheiben (Hash)
|
||||
# isConsumptionRecommended - ist Verbrauch empfohlen ?
|
||||
# dswoncond - Device zur Lieferung einer zusätzliche Einschaltbedingung
|
||||
@ -7590,12 +7634,13 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
|
||||
|
||||
<ul>
|
||||
<a id="SolarForecast-set-currentInverterDev"></a>
|
||||
<li><b>currentInverterDev <Inverter Device Name> pv=<Readingname>:<Einheit> etotal=<Readingname>:<Einheit> </b> <br><br>
|
||||
<li><b>currentInverterDev <Inverter Device Name> pv=<Readingname>:<Einheit> etotal=<Readingname>:<Einheit> [capacity=<max. WR-Leistung>] </b> <br><br>
|
||||
|
||||
Legt ein beliebiges Device und dessen Readings zur Lieferung der aktuellen PV Erzeugungswerte fest.
|
||||
Es kann auch ein Dummy Device mit entsprechenden Readings sein.
|
||||
Die Werte mehrerer Inverterdevices führt man z.B. in einem Dummy Device zusammen und gibt dieses Device mit den
|
||||
entsprechenden Readings an. Die Bedeutung des jeweiligen "Readingname" ist:
|
||||
entsprechenden Readings an. <br>
|
||||
Die Angabe von <b>capacity</b> ist optional, wird aber zur Optimierung der Vorhersagegenauigkeit dringend empfohlen.
|
||||
<br>
|
||||
|
||||
<ul>
|
||||
@ -7604,16 +7649,17 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
|
||||
<tr><td> <b>pv</b> </td><td>Reading welches die aktuelle PV-Erzeugung liefert </td></tr>
|
||||
<tr><td> <b>etotal</b> </td><td>Reading welches die gesamte erzeugten Energie liefert (ein stetig aufsteigender Zähler) </td></tr>
|
||||
<tr><td> <b>Einheit</b> </td><td>die jeweilige Einheit (W,kW,Wh,kWh) </td></tr>
|
||||
<tr><td> <b>capacity</b> </td><td>Bemessungsleistung des Wechselrichters gemäß Datenblatt (max. möglicher Output in Watt) </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<ul>
|
||||
<b>Beispiel: </b> <br>
|
||||
set <name> currentInverterDev STP5000 pv=total_pac:kW etotal=etotal:kWh <br>
|
||||
set <name> currentInverterDev STP5000 pv=total_pac:kW etotal=etotal:kWh capacity=5000 <br>
|
||||
<br>
|
||||
# Device STP5000 liefert PV-Werte. Die aktuell erzeugte Leistung im Reading "total_pac" (kW) und die tägliche Erzeugung im
|
||||
Reading "etotal" (kWh)
|
||||
Reading "etotal" (kWh). Die max. Leistung des Wechselrichters beträgt 5000 Watt.
|
||||
</ul>
|
||||
</li>
|
||||
</ul>
|
||||
@ -8177,9 +8223,9 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
|
||||
Ist der Schüssel "auto" definiert, kann der Automatikmodus in der integrierten Verbrauchergrafik mit den
|
||||
entsprechenden Drucktasten umgeschaltet werden. Das angegebene Reading wird ggf. im Consumer Device angelegt falls
|
||||
es nicht vorhanden ist. <br>
|
||||
Mit dem optionalen Schlüssel "swoncond" kann eine zusätzliche externe Bedingung definiert werden um den Einschaltvorgang des
|
||||
Consumers freizugeben. Ist die Bedingung (Regex) nicht erfüllt, erfolgt kein Einschalten des Verbrauchers auch die
|
||||
sonstigen Voraussetzungen wie Auto-Planung, mode, vorhandene PV-Leistung usw. gegeben sind.
|
||||
Mit dem optionalen Schlüssel <b>swoncond</b> kann eine <b>zusätzliche externe Bedingung</b> definiert werden um den Einschaltvorgang des
|
||||
Consumers freizugeben. Ist die Bedingung (Regex) nicht erfüllt, erfolgt kein Einschalten des Verbrauchers auch wenn die
|
||||
sonstigen Voraussetzungen wie Zeitplanung, mode, vorhandene PV-Leistung usw. gegeben sind.
|
||||
<br><br>
|
||||
<ul>
|
||||
<table>
|
||||
@ -8206,7 +8252,7 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
|
||||
<tr><td> <b>auto</b> </td><td>Reading im Verbraucherdevice welches das Schalten des Verbrauchers freigibt bzw. blockiert (optional) </td></tr>
|
||||
<tr><td> </td><td>Readingwert = 1 - Schalten freigegeben (default), 0: Schalten blockiert </td></tr>
|
||||
<tr><td> <b>pcurr</b> </td><td>Reading welches den aktuellen Energieverbrauch (z.B. Schaltdose mit Energiemessung) liefert und Einheit (W/kW) (optional) </td></tr>
|
||||
<tr><td> <b>etotal</b> </td><td>Reading:Einheit (Wh/kWh), welches die Summe der verbrauchten Energie liefert (optional) </td></tr>
|
||||
<tr><td> <b>etotal</b> </td><td>Reading:Einheit (Wh/kWh) des Consumer Device, welches die Summe der verbrauchten Energie liefert (optional) </td></tr>
|
||||
<tr><td> <b> </td><td>:<Schwellenwert> (Wh) - optionaler Energieverbrauch pro Stunde ab dem der Verbraucher als aktiv gewertet wird. </td></tr>
|
||||
<tr><td> <b>swoncond</b> </td><td>zusätzliche Bedingung die erfüllt sein muß um den Verbraucher einzuschalten (optional). </td></tr>
|
||||
<tr><td> </td><td><b>Device</b> - Device zur Lieferung der zusätzlichen Einschaltbedingung </td></tr>
|
||||
|
Loading…
x
Reference in New Issue