define <name> Heating_Control <device> <profile> <command>|<condition>
set <device> (desired-temp|desiredTemerature) <temp>
The following parameter are defined:
Example:
define HCB Heating_Control Bad_Heizung 12345|05:20|21 12345|05:25|comfort 17:20|21 17:25|eco
define HCW Heating_Control WZ_Heizung 07:00|16 Mo,Tu,Th-Fr|16:00|18.5 20:00|12
{fhem("set dummy on"); fhem("set @ desired-temp %");}
At the given times and weekdays only(!) the command will be executed.
define HCW Heating_Control WZ_Heizung Sa-Su,We|08:00|21 (ReadingsVal("WeAreThere", "state", "no") eq "yes")
The temperature is only set if the dummy variable WeAreThere is "yes".
define <name> Heating_Control <device> <profile> <command>|<condition>
set <device> (desired-temp|desiredTemerature) <temp>
Folgende Parameter sind im Define definiert:
Beispiel:
define HCB Heating_Control Bad_Heizung 12345|05:20|21 12345|05:25|comfort 17:20|21 17:25|eco
define HCW Heating_Control WZ_Heizung 07:00|16 Mo,Di,Mi|16:00|18.5 20:00|12
{fhem("set dummy on"); fhem("set @ desired-temp %");}
Zu den definierten Schaltzeiten wird nur(!) der in {} angegebene Perl-Code ausgeführt.
define HCW Heating_Control WZ_Heizung Sa-So,Mi|08:00|21 (ReadingsVal("WeAreThere", "state", "no") eq "yes")
Die zu setzende Temperatur wird nur gesetzt, falls die Dummy Variable WeAreThere = "yes" ist.